The KHJ0.2/12 mining emergency stop is used for the place under coal mine with coal dust and methane explosive gas, and is used as a control of emergency stop for belt conveyor protection device. When an emergency occurs, pulling the emergency stop at any place along the site can send out the stop signal to realize the protection of the personal and Belt Conveyor .
The emergency has reliable performance, simple structure, good safety performance, and easy to use and other characteristics.
II. Ambient condition
1. Normal working condition
a) Altitude less than 2000m.
b) Ambient temperature within 10℃~+40℃.
c) Relative humidity not over 95% (25℃).
d) Atmospheric pressure: 80kPa~106kPa.
e) The place under mine with coal dust and methane explosive gas.
f) The place without corrosive gas which could damage metal and insulation.
g) The place without heavy vibrations or bumps.
h) Installation type: I type.
i) Pollution grade: 3.
2. The worst ambient condition of storage and transportation.
a) High temperature: +60℃.
b) Low temperature: -40℃.
c) Relative humidity not over 95% (25℃).
d) Vibration: accelerated speed 50m/s².
e) Impact: peak accelerated speed 500m/s².
III. Technical features
1. Product Model and Significance
2. Mining intrinsically safe type, explosion proof Mark: ExibI Mb. This product is comply with the regulation in GB3836.4-2010.
3. Main technical parameter:
3.1 Performance parameter
a) Contact capacity: DC 12.5V/0.5A.
b) Contact resistance: ≤0.1Ω.
c) Contacts pairs: one pair of normal open contact.
d) Action travel: 8~30mm.
e) Action force:80~120N.
f) Reset force:20~50N.
g) Action features: self-locking during protection, manual reset.
3.2 working duty: uninterrupted duty.
3.3 Main functions: It could complete the protection of emergency stop for Belt Conveyor Protection device.
IV. Structure features
The external dimension of the emergency stop is 164*198*101mm, as shown below. External shell material: PA Plastic. Weight: 2kg
V. Working Process and Principle
This product is lever cam structure. To pull any rope of both side, the cam is drive by the lever, making the switch change, send out stop signal. The emergency stop is locked automatically after action, if the accident is pulling any side of the rope, the cam is driven by lever to make the switch action switch and send out the stop signal. Automatic locking after emergency stop locking switch action, after the accident being disposed, it can be reset manually to initial status.
VI. Installation and wiring
1. Location hole size:
2. Wiring
Remove the terminal cover, connect the cable according to the drawing, fix the screw after wiring, then it can be used.
3. Installation attentions
a) To make a installation plate according to shape of the emergency stop, installing the emergency stop on it, and then fix them on both side of the belt conveyor, and the following conditions should be met:.
b) The emergency stop should be lower than the belt level for convenient operation.
c) To fasten the pull rope (φ4mm) on each pull rings, better length of each rope is ≤60m, along the belt conveyor, and hanging ring should be installed on each 10m for supporting purpose to reduce deflection.
d) After installing the emergency stop, the rope on both sides should be with suitable tension, the deflection should be as small as possible, and the switch should not be reset automatically after pulling the rope.
e) To fasten the compression nut when wiring, otherwise it will not play the role of moisture-proof and dust proof, and it will affect the electrical performance after long time.
VII. Usage attention
1. The emergency stop protection of the belt conveyor is determined by the emergency stop, and the emergency stop is installed after debugging, the working condition of the emergency stop directly determines whether comprehensive protection device can work normally, so the non-professional personnel is not allowed to pull the emergency.
2. The maintenance personnel should regularly check the condition of each part of the emergency stop, the problems must be dealt with in time.
3. The improper changes of internal components wiring may cause equipment damage, our company does not bear the liability and economic losses caused by above-mentioned accident.
Huafei Company could provide complete Coal Mine Control , incude Water Pump Control , Auto Water Pump Switcher, Automatic Water Pump Controller, Hoist Electric Control, Split Type Control Table for Hoist and Winch, Water Pump Control, Electric Aotumation , Medium Power Supply Control, Winch Control , Belt Conveyor Energy Control, Belt Conveyor Control , Automatic Control For Ventilator, Explosion Proof Vfd , General Vfd , Explosion Proof Sensor , Automatic Control Sensor, Smart Electric Driveand other Winch Protection Hoist Protection .
Product Categories : Electric Aotumation > Belt Conveyor Control
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.